Jensprima online hardness and residual chlorine analyzers play a vital role in the service life of reverse osmosis membranes and the water recovery rate within pharmaceutical RO systems.
The Flumsys 10TC Single Channel Digital Controller is designed to measure a single parameter relevant to the water treatment industry and can be customized to measure multi-parameters, supporting JENSPRIMA sensors only. The 4.3" colour LCD display is touch operated and very easy to set up.
Wide power input, touch screen design
2x programmable Hi/Lo relay outputs
2x isolated 4-20mA outputs
RS485 Modbus RTU communication
| Display | 4.3-inch colour LCD touch screen display |
| Language | Chinese/English |
| Password | Setup mode: 0022, Calibration mode:11 |
| Power Supply | 90-260VAC, 50/60Hz |
| Current Output 1 | Isolated 4-20mA output, measurable value can be set,maximum load 500Ω. |
| Current Output 2 | Isolated 4-20mA output, measurable value can be set,maximum load 500Ω. |
| Digital Communication | RS485 Modbus RTU |
| Alarm Output | 2 sets of programmable Hi/Lo contacts with hysteresis setting 5A/250VAC/30VDC |
| Cleaning Relay | Cleaning interval:0.1-1000h, |
| Cleaning Time | 1-1000S |
| Working Temperature | -10-60.0°C |
| Storage Temperature | -20-70.0°C |
| Protection Class | IP66 |
| Installation | Wall mounting |
| Size | 200×180×90mm |
| Weight | ca.1kg |
| Potentiostatic Sensor innoSens 710 | |
| Product Type | innoSens 710 |
| Measuring Range | 0-2.000/0-20.00ppm (mg/L) |
| Resolution | 0.001/0.01ppm |
| Accuracy | ±2%f.s. |
| Temperature Compensation | PT1000 (optional) |
| pH Compensation | 0-60℃ |
| Operating Temperature | Manual pH compensation |
| Recommended Flow Rate | 10-30l/h |
| Electrode Material | Glass |
| Threaded Connection | PG13.5 |
| Cable Length | 3m as standard, 10m optional |
| Size | φ12mm×120mm |
| innoSens 730 Residual Chlorine Electrodes | |
| Measuring Range | 0-20.00mg/L,0-200.00mg/L |
| Resolution | 0.001/0.01mg/L |
| pH Range | 4.0-9.0 |
| Working Temperature | 0-45℃ |
| Pressure | Max.3bar |
| Flow Rate | 250~500ml/min |
| Response Time | Initial polarisation time about 2 hours |
| innoSens 740 Total Chlorine Electrode | |
| Measuring Range | 0.005-2.000mg/L, 0-20.00mg/L |
| Resolution | 0.001/0.01mg/L |
| pH Range | 4.0-12.0 |
| Working Temperature | 0-45℃ |
| Pressure | Max.3bar |
| Flow Rate | 250~500ml/min |
| Response Time | Initial polarisation time about 2 hours |
| innoSens 745 Chlorine Dioxide Electrode | |
| Measuring Range | 0-2.000mg/L, 0-200.00mg/L |
| Resolution | 0.001/0.01mg/L |
| pH Range | 1.0-12.0 |
| Working Temperature | 0-45℃ |
| Pressure | Max.1bar |
| Flow Rate | 250~500ml/min |
| Response Time | Initial polarisation time about 1 hours |
| innoSens 750 Ozone Electrode | |
| Measuring Principle: | Membrane covered amperometric |
| Measuring Parameter: | Ozone |
| Measuring Range: | 0.005-2.000/0.05-20.00mg/L(ppm) |
| Repeatability: | ± 5% |
| Slope Drift: | about <-1%> |
| Working Temperature: | 0-45°C |
| Compensation: | built-in temperature sensor |
| Working Rressure: | Max 0.5bar |
| Flow Rate: | 200-500mlmin |
| pH Range: | 2-11pH ,4-9pH is recommended for pure water. |
| Polarisation Time: | approx. 1 hour for initial use |
| Zero Adjustment: | not required |
| Slope Calibration: | single point calibration according to DPD method |
| Material: | UPVC, ABS |
| Dimensions: | Outer diameter 25mm, length 220mm |
| Storage: | electrode/membrane cap: 5-40°C electrolyte 5-35°C |
| Interference: | Residual chlorine (almost negligible), chlorine dioxide |
| Maintenance Interval: | membrane cap replacement cycle 1 year, electrolyte replacement cycle 3-6 months |
| Flumsys 10TC-F2-A | free chlorine controller 230 VAC |
| Flumsys 10TC-F2-B | free chlorine controller 24 VDC |
| Flumsys 10TC-F3-A | total chlorine controller 230 VAC |
| Flumsys 10TC-F3-B | total chlorine controller 24 VDC |
| Flumsys 10TC-F4-A | chlorine dioxide controller 230 VAC |
| Flumsys 10TC-F4-B | chlorine dioxide controller 24 VDC |
| Flumsys 10TC-F5-A | ozone controller 230 VAC |
| Flumsys 10TC-F5-B | ozone controller 230 VAC |
| 37-0710-00 | innoSens 710 Double platinum electrodes, cable 3m |
| 37-0710-10 | innoSens 710 Double platinum electrodes, cable 10m |
| 35-0730-01 | innoSens 730-R1,0-20.00mg/L |
| 35-0730-02 | innoSens 730-R2,0-200.00mg/L |
| 35-0740-01 | innoSens 740-R1,0.005-2.000mg/L |
| 35-0740-02 | innoSens 740-R2,0-20.00mg/L |
| 50-0700-30 | PA-730 flow cell,acrylic material |
| 35-0745-01 | innoSens 745-R1,0-2.000mg/L |
| 35-0745-02 | innoSens 745-R2,0-200.00mg/L |
| 50-0700-30 | PA-730 flow cell,acrylic material |
| 35-0750-01 | innoSens 750-R1,0.005-2.000ppm |
| 35-0750-02 | innoSens 750-R2,0.05-20.00ppm |
| 50-0700-30 | PA-730 flow cell,acrylic material |
| 50-0700-30 | PA-730 flow cell,acrylic material |