multi parameter water quality analyzer
Phenolphthalein Alkalinity Analyzer
PACON 4900
HOME PRODUCS PARAMETERS Alkalinity Total Alkalinity Analyzer Phenolphthalein Alkalinity Analyzer PACON 4900


Phenolphthalein Alkalinity Analyzer PACON 4900
Phenolphthalein Alkalinity Analyzer PACON 4900

Phenolphthalein Alkalinity Analyzer PACON 4900


PACON 4900 is a compact, easy to operate and accurate on-line analyzer from JENSPRIMA for the automatic on-line measurement of phenolphthalein alkalinity and quality control of boiler water. The titrimetric colour change principle allows the measurement of high and low ranges by selecting different reagents.



Product Features:


1、Durable, accurate analyzer method (titration for colour change)

2、Automatic on-line monitoring, only one reagent required

3、Special material measuring bath, no condensation on optics

4、Stable measurements, generally no calibration required


  • Reagents SelectedTP5050 :0.2 – 5mmol/L 、TP5200 :0.8 – 20mmol/L
    Accuracy±5% of the maximum value of the selected reagent
    Repeatability±2.5% of the maximum value of the selected reagent Titrimetric colour change method
    Reagent Consumption0.05-0.6ml/per analysis
    Reagent Expiry2 years from the factory
    Analysis Timeca. 3 min depending on phenolphthalein alkalinity concentration and set rinse time 
    Measurement Interval5-360 min optional
    Automatic CleaningThe instrument is automatically rinsed after each measurement
    CalibrationService menu manual calibration
    Ambient Temperature10-45℃
    Water Sample Temperature5-40℃
    Water Sample Pressure0.5-5 bar, 1-2 bar recommended
    Water Quality RequirementsClear, colourless, no suspended matter, no air bubbles, pH>8.2
    Power Supply100-240VAC,50/60Hz
    Power Consumption20W (at work),3.5W (at standby)
    Inlet/Outlet6mm hose, open discharge no back pressure discharge
    Current Output0/4-20mA
    Relay Output4 passive NC/NO relay outputs, 250VAC/1A
    External Input2 programmable input contacts
    Protection ClassIP65
    Dimensions300×300×200mm
    Weightca. 4Kg
  • Order No.

    Description

    33-4900-00

    PACON 4900 Online Phenolphthalein Alkalinity Analyzer

    50-4905-01

    TP5050 phenolphthalein alkalinity

    50-4920-01

    TP5200 phenolphthalein alkalinity

     

    50-5000-10

    Spare Parts Kit Including pump head

    (including pump tube), all seals, stirrups, connection pipe of reagent  bottle,

    recommend to exchange every year.


Datasheet Download






Online Message
We will manage and protect the privacy of the personal information
  • Name
  • E-Mail
  • Telephone
  • Message Content

footer_background
Service Repair Form
Tell us what issue you encountered, including any steps or symptoms.
  • Name
  • Email
  • Phone
  • Fault Description

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.